HOW TO CALIBRATE A MEDICAL OXYGEN SENSOR – Credihealth Blog

The majority of Liquify Oxygen sensing units need one-point or two-point calibration. Prior to a one-point calibration can be performed, the right barometric pressure information should be fed into the sensing unit’s meter. The two-point calibration runs in a zero-oxygen service which is normally prepared by liquifying a zero-oxygen tablet in 40ml of pure or deionized water. The sensing unit’s design number identifies the sort of calibration it runs on and this details can be gotten on the item handbook or by browsing up the design number on an online search engine online.

A common sensing unit is created to suit the flue of a gas or biogas boiler. It is likewise linked to a V25 variation XY-LC user interface board. This suggests that the voltage output is within 0 to 10 volts representing 25% oxygen.

The sensing units do not require a recommendation gas, suggesting that there is definitely no requirement to get a specific gas concentration to one side of the sensing unit. Whatever is linked, and this makes such activity unneeded.

Here are some guides to follow in the calibration of oxygen sensing units:

  • To carry out the calibration, the calibration input of the board is to be short-circuited to no volts for a 2nd or more. Nevertheless, this depends upon the kind of sensing unit utilized. Some of them would require a manual short-circuit, others are done with a switch, while some have been digitally automated to do the short-circuiting on their own without any human operator needed. Some automated sensors also autocorrect according to the surrounding temperature which enables them to be operated in the laboratory (indoors) or on the field (outdoors).
  • Gas detectors that are equipped with electrochemical oxygen sensors of either one-point or two-point calibration should be set to 20.9% by volume in outside fresh air before indoor use or for other enclosed places. This function is frequently called “auto-set” or “zeroing” of the oxygen sensing unit and is really the process of using outside fresh air as a 20.9% by volume oxygen calibration gas standard (in atmospheres up to 14,000 ft. elevation).
  • The sensors do not require two-point calibration. Neither do they need to be on zero volts to offset calibration? They simply need a span calibration, which can be done with almost any kind of gas. The simplest way to do it is in the fresh air, and it measures oxygen.
  • Water calibrations are more capable of stabilizing temperature than air calibrations. They are therefore better utilized outdoors than indoors.
  • Operating the sensors need serious caution because they are extremely hot. Oxygen sensing units are heated up to 700 Celsius (700⁰C). They are usually protected by an equipped porous cap whose temperature level can reach up to 250 Celsius (700⁰C). It must not be touched.
  • The calibration gas cylinder usually indicates a date of preparation and a recommended expiration date. Usually, Product manuals include the procedures for calibration operations in a maintenance section of the manual. This may indicate one or more oxygen gas bottles of different concentrations are necessary to set a “calibration window” for the device.
  • It is possible in some oxygen monitoring instruments such as the ENMET AM-5175, ISA-40, ISA-42M, ISA-50M, and ISA-60M to use the surrounding air in which the sensor is located to set the oxygen reading to 20.9%, which ought to appear on the LCD display of the device.

You can find more information on how to calibrate a medical oxygen sensing unit here.

Disclaimer: The declarations, viewpoints, and information consisted of in these publications are entirely those of the specific authors and factors and not of Credihealth and the editor(s). 